    Buy cheap Thermocouple Type K Extension Cable For Temperature Compensation from wholesalers
     
    Buy cheap Thermocouple Type K Extension Cable For Temperature Compensation from wholesalers
    • Buy cheap Thermocouple Type K Extension Cable For Temperature Compensation from wholesalers
    • Buy cheap Thermocouple Type K Extension Cable For Temperature Compensation from wholesalers
    • Buy cheap Thermocouple Type K Extension Cable For Temperature Compensation from wholesalers
    • Buy cheap Thermocouple Type K Extension Cable For Temperature Compensation from wholesalers

    Thermocouple Type K Extension Cable For Temperature Compensation

    Ask Lasest Price
    Brand Name : DLX
    Model Number : Type k Thermocouple extension wire
    Certification : CE,ROHS
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 300 tons per month
    Delivery Time : 5-21 days
    • Product Details
    • Company Profile

    Thermocouple Type K Extension Cable For Temperature Compensation

    Thermocouple Type K Extension Cable for Temperature Compensation


    The compensation wire models are divided into SC, KC, KX, EX, JX, TX according to the product variety.

    Among them: a) The first letter of the model corresponds to the graduation number of the thermocouple;

    b) The letter "X" represents the extended compensation wire (type)

    c) The letter "C" represents the compensation type compensation wire (type)

    Note: SC type compensation wires can be equipped with R-type indexing thermocouples.

    • Thermocouple Extension Wire

    Type K Extension Cable 0.5*2 red black pvc insulation with pvc sheath. The conduct is thermocouple type K material which is nickel-chrome with nickel-siliconor nickel-aluminum. The construction is similar to pair instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometer are electrically conducted by thermocouple extension cables / thermocouple compensating cables. The conductors used for these thermocouple cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature.

    Basically, Fine Wire Thermocouple grade wires are used to make sensing points of thermocouples. However, a Thermocouple Extension Wire is only used to extend a thermocouple signal back from the probe to the instrument reading it. A thermocouple Extension Cable is used in lower ambient temperatures. It may pass a signal representing a higher temperature than it received from the probe. However, Type K Thermocouple Extension Wire may not be physically exposed to that high temperature. A Stranded Thermocouple Wire can be used as an extension wire but an extension wire cannot be used in a Flexible Thermocouple Wire as a sensing point. The usable length of these wires differs based on numerous factors.



    • Thermocouple Wire
    CodeWires component of the thermocouple
    +Positive leg-Negative leg
    NNi-cr-si (NP)Ni-si-magnesium (NN)
    KNi-Cr (KP)Ni-Al(Si) (KN)
    ENi-Cr (EP)Cu-Ni<constantan> (EN)
    JIron (JP)Cu-Ni<constantan> (JN)
    TCopper (TP)Cu-Ni<constantan> (TN)


    • ​Standards
    ASTMANSIIECDINBSNFJISGOST
    (American Society for Testing and Materials) E 230(American National Standard Institute) MC 96.1(European Standard by the International Electrotechnical Commission 584)-1/2/3(Deutsche Industrie Normen) EN 60584 -1/2(British Standards) 4937.1041, EN 60584 - 1/2(Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324(Japanese Industrial Standards) C 1602 - C 1610(Unification of the Russian Specifications) 3044

    Detailed Parameter of thermocouple wire

    Working Temperature Range


    Diameter/mmLong time Working temperature /ºCShort period Working temperature /ºC
    0.3700800
    0.5800900
    0.8,1.09001000
    1.2,1.610001100
    2.0,2.511001200
    3.212001300

    Thermocouple No. indexingCompensation wire typeUsag ClassificationMeasuring junction temperature / ℃standard EMF value/μVPrecision gradeGeneral grade
    Tolerance μVThermal EMF range μVTolerance μVThermal EMF range μV
    SorRSC or RCG100646±30616~676±60586~706
    H100646--±60586~706
    2001 1441--1.381~1 501
    KKX,KCAG-25-968±40-924~-1 012±80-880~-1 056
    or KCB1004 0964 052~4 1404 008~4 184
    H-25-968±40-924~-1 012±88-880~-1 056
    1004 0964 052~4 1404 008~4 184
    2008 1388 094~8 1828 050~8 226
    NNX or NCG-25-646±43-603~-689±86-560~-732
    1002 7742 731~2 8172 688~2 860
    H-25-646±43-603~-690±86-560~-732
    1002 7742 731~2 8172 688~2 860
    2005 9135 870~5 9565 827~5 999
    EEXG-25-1 432±81-1 351~-1 513±138-1 294~-1 570
    1006 3196 238~ 64006 181~6 457
    H-25-1 432±81-1 351~- 1513±138-1 294~-1 570
    1006 3196 238~6 4006 181~6 457
    20013 42113 340~13 50213 283~13 559
    JJXG-25-1 239±62-1 177~-1 301±123-1 116~-1 362
    1005 2695 207~5 3315 146~5 392
    H-25-1 239±62- 177~-1 301±123-1 116~-1 362
    1005 2695 207~5 3315 146~5 392
    20010 77910 717~10 84110 656~10 902
    TTXG-25-940±30-910~-970±60-850~-1 000
    1004 2794 249~4 3094 189~4 339
    H-25-940±48-892~-988±90-850~-1 030
    1004 2794231~4 3274 189~4 369
    200



    Size range



    Wire: 0.12 to 8.0 mm.


    • Type N Accuracy (whichever is greater):
    • Maximum continuous operating temperature: up to 2,300F (1,260C)

    • Short term use: 2,336F (1,280C)

    • Thermocouple grade wire, -454 to 2300F (-270 to 1,260C)